PRODUCTION DESCRIPTION
R32 or R410a DC Inverter Heat Pump (ErP A++, ErP A+++) with EVI compressor technology and full inverter technology for extremely cold area and high outlet water temperature. Equipped with heating, cooling and domestic hot water functions for families, apartments, small industrial sites, etc. Additionally, it can work with solar, boiler or electric heater according to the practical condition of the heating system. With R410a refrigerant, most advance inverter technology & intelligent defrost function to work well in -35ºC, which is much more higher efficiency than normal air source heat pump.
KEY FEATURES
1) Extended working range down to -35°C ambient (low ambient type)
2) 5 modes: heating only, heating+DHW, cooling only, cooling+DHW, DHW only
3) Low running costs and high efficiency
4) Long-life and corrosion resistant composite cabinet stands up to severe climates
5) Famous compressor ensures outstanding performance and durability
6) LCD touch screen with self-diagnostic control function
7) With control output for three-way valve
8) Easy operation and simple installation
9) WIFI control function is optional
KEY COMPONENTS
Blueway has its own R&D team & professional test laboratory, which has developed mature control system. Inverter units with accurate temperature control by DC inverter technology, with multi-protection, automatic defrost, WI-FI control function, etc.
The units are supplied with micro processor based digital controller with LCD touch display. The controller is programmed to provide a maximum protection to the heat pump system and accurate temperature control. The control panel is completely factory wired with all accessories and terminals included.
High corrosion resistance
High thermal efficiency
High working temperature
High efficienty and energy saving
Quiet operation due to less moving parts
Adopt famous brand rotary or scroll compressor
Energy saving pump with constant volume or pressure adjustment function. German Wilo or Chinese Shinoo water pump is optional.
APPLICATION DIAGRAM
Split Type:
Monoblock Type:
TECHNICAL SPECIFICATIONS
Options: EVI Low Ambient & Normal Ambient Type (Split & Monoblock Type)
DC Inverter Heat Pump (Split Type)
Model
EDHP-09S
EDHP-14S
EDHP-16S
EDHP-24S
EDHP-30S
HP
3
5
6
8
10
Power supply
Indoor unit
V/Hz/Ph
220-240/50/1, 380-415/50/3
Outdoor unit
V/Hz/Ph
220-240/50/1
380-415/50/3
+7°C/35
°C
Floor heating
Heating capacity
kW/h
9
14
16
24
30
Power input
kW
2
3.04
3.5
5.4
7.3
COP
-
4.5
4.6
4.56
4.45
4.1
+2
°C
/35
°C
Floor heating
Heating capacity
kW/h
8.5
12.5
14.3
21.7
28
Power input
kW
2.18
3.13
3.7
5.5
7.2
COP
-
3.9
4.0
3.92
4.0
3.9
-7
°C
/35
°C
Floor heating
Heating capacity
kW/h
7.1
11
13
18.9
24
Power input
kW
2.4
3.61
4.4
6.52
8
COP
-
2.96
3.05
2.95
2.9
3
+7
°C
/45
°C
Radiators
Heating capacity
kW/h
8.5
13
15
20.6
29
Power input
kW
2.4
3.6
4.41
5.9
8.5
COP
-
3.54
3.62
3.4
3.5
3.4
-7
°C
/45
°C
Radiators
Heating capacity
kW/h
6.8
10.2
12.5
18.0
22
Power input
kW
2.9
4.23
5.2
7.6
9.6
COP
-
2.34
2.41
2.4
2.37
2.3
+7
°C
/55
°C
Hot water
Heating capacity
kW/h
6
12
14
20
24
Power input
kW
2.26
4
4.91
7.1
9.2
COP
-
2.65
3
2.85
2.8
2.6
-12
°C
/41
°C
Floor heating
Heating capacity
kW/h
6
10.5
11.5
17.8
22
Power input
kW
2.6
4.5
5.1
7.74
9.6
COP
-
2.3
2.36
2.26
2.3
2.3
+35°C/7°C
Fan coil
Cooling capacity
kW/h
7
11
13
20
24
Power input
kW
2.6
3.95
4.81
7.25
9.2
EER
-
2.7
2.8
2.7
2.76
2.6
Energy efficiency class
Floor heating
-
A++
A++
A++
A++
A+
DHW mode
-
A+
A+
A+
A+
A+
Heating operation range
Ambient
°C
-25~25
Water side
°C
18~60
Cooling operation range
Ambient
°C
10~43
Water side
°C
7~22
Domestic hot water operation range
Ambient
°C
-25~35
Water side
°C
25~60
Rated water flow rate
m³/h
1.5
2.4
2.8
4.1
5.2
Rated pressure drop
kPa
30
45
45
40
47
Max. working pressure
Refrigerant
Bar
44
44
44
44
44
Water
Bar
7
7
7
7
7
Controller
-
Micro processor based digital wire controller with LCD display
External cabinet
-
Galvanized steel with powder coating
Compressor
Type
-
Rotary
Rotary/Scroll
Qty.
Nos.
1
1
1
1
1
Refrigerant
-
R32/R410a
Water heat exchanger
-
SUS 316 Brazed plate heat exchanger
Electric heater
kW
3/6
6
Water pump
-
DC type, Wilo/Shinhoo
Shinhoo
Expansion tank
L
5
8
10
Water connection
Inlet&Outlet
inch
1"
1"
1"
1"
1-1/4"
Noise level
Indoor Unit
dB(A)
42
42
42
42
42
Outdoor Unit
dB(A)
52
56
58
59
61
Net dimension (W*D*H)
Indoor Unit
mm
522*296*863.5
522*296*863.5
522*296*863.5
522*296*863.5
602*308*880
Outdoor Unit
mm
950*445*800
976*410*1273
940*448*1365
1150*480*1565
1405*590*1626
Net weight
Indoor Unit
kg
55
55
55
55
70
Outdoor Unit
kg
58
90
100
120
175
Rough loading
20GP/40GP/40HQ
set
24/48/48
23/48/52
23/48/52
19/41/41
12/27/27
Notes:
1.The values of heating(cooling) capacity/power input/COP(EER) are based on measurement of EN14511 standard.Usage environment, such as operation of the heat pump, room temperature and controller adjustments, may cause disparities between practically determined and these values;
2.Sound pressure level measured at distance of 1m from the device;
3.For wall-mounted type, the compressor is located in the outdoor unit;
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
DC Inverter Heat Pump (Monoblock Type)
Model
EDHP-09M
EDHP-14M
EDHP-16M
EDHP-24M
EDHP-30M
HP
3
5
6
8
10
Power supply
V/Hz/Ph
220-240/50/1
380-415/50/3
+7
°C
/35
°C
Floor heating
Heating capacity
kW/h
9
14
16
24
30
Power input
kW
2
3.04
3.5
5.4
7.3
COP
-
4.5
4.6
4.56
4.45
4.1
+2
°C
/35
°C
Floor heating
Heating capacity
kW/h
8.5
12.5
14.3
21.7
28
Power input
kW
2.18
3.13
3.7
5.5
7.2
COP
-
3.9
4.0
3.92
4.0
3.9
-7
°C
/35
°C
Floor heating
Heating capacity
kW/h
7.1
11
13
18.9
24
Power input
kW
2.4
3.61
4.4
6.52
8
COP
-
2.96
3.05
2.95
2.9
3
+7
°C
/45
°C
Radiators
Heating capacity
kW/h
8.5
13
15
20.6
29
Power input
kW
2.4
3.6
4.41
5.9
8.5
COP
-
3.54
3.62
3.4
3.5
3.4
-7
°C
/45
°C
Radiators
Heating capacity
kW/h
6.8
10.2
12.5
18.0
22
Power input
kW
2.9
4.23
5.2
7.6
9.6
COP
-
2.34
2.41
2.4
2.37
2.3
+7
°C
/55
°C
Hot water
Heating capacity
kW/h
6
12
14
20
24
Power input
kW
2.26
4
4.91
7.1
9.2
COP
-
2.65
3
2.85
2.8
2.6
-12
°C
/41
°C
Floor heating
Heating capacity
kW/h
6
10.5
11.5
17.8
22
Power input
kW
2.6
4.5
5.1
7.74
9.6
COP
-
2.3
2.36
2.26
2.3
2.3
+35
°C
/7
°C
Fan coil
Cooling capacity
kW/h
7
11
13
20
24
Power input
kW
2.6
3.95
4.81
7.25
9.2
EER
-
2.7
2.8
2.7
2.76
2.6
Energy efficiency class
Floor heating
-
A++
A++
A++
A++
A+
DHW mode
-
A+
A+
A+
A+
A+
Heating operation range
Ambient
°C
-25~25
Water side
°C
18~60
Cooling operation range
Ambient
°C
10~43
Water side
°C
7~22
Domestic hot water operation range
Ambient
°C
-25~35
Water side
°C
25~60
Rated water flow rate
m³/h
1.5
2.4
2.8
4.1
5.2
Rated pressure drop
kPa
30
45
45
40
47
Max. working pressure
Refrigerant
Bar
44
44
44
44
44
Water
Bar
7
7
7
7
7
Controller
-
Micro processor based digital wire controller with LCD display
External cabinet
-
Galvanized steel with powder coating
Compressor
Type
-
Rotary
Rotary/Scroll
Qty.
Nos.
1
1
1
1
1
Refrigerant
-
R32/R410a
Water heat exchanger
-
SUS 316 Brazed plate heat exchanger
Electric heater (optional)
kW
3/6
6
Water pump (optional)
-
DC type, Wilo/Shinhoo
Shinhoo
Expansion tank (optional)
L
5
8
10
Water connection
Inlet&Outlet
inch
1"
1"
1"
1"
1-1/4"
Noise level
dB(A)
52
56
58
59
61
Net dimension (W*D*H)
mm
1160*430*820
1079*430*1273
1079*430*1368
1150*480*1565
1405*590*1626
kg
75
130
145
157
230
Rough loading
20GP/40GP/40HQ
set
42/92/92
26/54/54
26/54/54
19/41/41
12/27/27
Notes:
1.The values of heating(cooling) capacity/power input/COP(EER) are based on measurement of EN14511 standard.Usage environment, such as operation of the heat pump, room temperature and controller adjustments, may cause disparities between practically determined and these values;
2.Sound pressure level measured at distance of 1m from the device;
3.If local ambient temperature will be below 0°C in winter, please use an approved antifreeze solution;
Blueway reserves the rights to modify the above specifications without notice for product improvement. Please contact us for updated information.
MANUFACTURING & SHIPMENT
ADVANTAGES & MARKET OVERVIEW
1.Blueway has around 30 years of rich HVAC manufacturing experience.
2.Over 1000 original R&D products, Blueway is qualified to be OEM/OBM/ODM.
3.Over 10000 engineering solutions with great success provided by Blueway.
4.Online technical service is available twenty-four hours a day without break.
5.Blueway intelligent control system with precise timing, temperature control & remote monitoring function.
With advanced technology and R&D capacity, Blueway has obtained over more than 20 patents and become one of the leading HVAC manufacturers in China. Meanwhile, 70% of Blueway products have been exported to oversea markets, including Australia, Europe, North America, Middle East, South Africa, South America and obtained worldwide recognition. Additionally, it has over 20 representative offices located in different cities of China, and also has its authorized distributors in Europe, Middle East, North America and South America.
So far, Blueway has already provided over 10000 engineering solutions with great success. What's more, Blueway is also the recommended brand by Hilton Hotel in Chinese market. Blueway will continue its endeavor and commitment to serve its worldwide partners by providing solutions and innovative products of high efficiency.
FAQ
Q: Which one is the hot selling model?
A: EDHP-16S is the hot sale model in European market, it can reach to 18kW heating capacity.
Q: What's the selling point of this product series?
A: This product series adopt Mitsubishi or Panasonic inverter rotary compressor, DC fan motor, DC watet pump for 3-8HP models, and can easily control the unit via mobile app after WIFI connection. And some models have already gotten ErP A++ labels from TUV certificate company.
Q: How about the refrigerant type?
A: For monoblock type, R32/R410a are optional. For split type, R32 & R410a are optional for EDHP-09 (3HP). But for EDHP-12/14/16/24/30 (4-10HP) only have R410a.
Q: How about the compressor?
A: Generally, we adopt Mitsubish or Panasonic inverter rotary compressor.
Q: What's the MOQ?
A: Generally, one unit of sample order is acceptable, but quotation will be a little higher than container order.
Q: How long is the warranty time?
A: Generally, one year for the whole unit, three years for the compressor.
Q: How about the after-sales service?
A: Generally, we only provide online technical support. So far, we have authorized distributors & repair centers in Europe, Middle East, North America & South America for the oversea markets.
If you are looking for more details, kindly visit electric wheel loader supplier, electric powered dump trucks, autonomous haulage solutions.